The AHU Manufacturer!

 

Shandong Kasuo Air Conditioning Equipment Co., Ltd., located in Luquantun Industrial Park, Dezhou, Shandong, benefits from excellent transport links near major railways and the Beijing-Hangzhou Grand Canal. The company employs 800 staff, including 296 technical experts and 35 senior engineers, and operates on a 270,000㎡ site with 150,000㎡ workshops. It features advanced production lines for refrigeration, fan coil units, and machine tools, supported by 80 sets of large-scale equipment.

 

 
  • Ceiling Cassette Air Conditioning

    Ceiling Cassette Air Conditioning features fully concealed installation, which saves floor space and maintains the unified aesthetic of interior decoration. It delivers wider air coverage with...

  • Ceiling Cassette Air Conditioning Unit

    The primary merit of Ceiling Cassette Air Conditioning Unit is its space-saving design. It eliminates bulky floor-standing cabinet units to keep interiors neat and elegant. It provides extensive...

  • Fresh Air Handling Units

    Fresh Air Handling Units are integrated air treatment equipment that combines fresh air intake, multi-stage filtration, heat recovery and intelligent air supply.
    Equipped with a...

  • Air Handling Unit (AHU)

    Air Handling Unit (AHU), also referred to as air cabinet or air conditioning cabinet, is a terminal air handling device for central air conditioning systems. It adopts water as the cold and heat...

  • Air Handling Unit

    Air Handling Unit is the core terminal equipment of central air conditioning systems, focusing on air purification, temperature and humidity control, fresh air supply, and circulation treatment....

  • Combined Type Air Handling Unit

    Combined Type Air Handling Unit is a modular, high-performance air treatment core equipment for central air conditioning systems. It integrates air mixing, filtering, cooling/heating,...

  • Purification Air Handling Unit

    Purification Air Handling Unit (PAHU) is an integrated air treatment equipment specially designed for environments with strict requirements on cleanliness, temperature, humidity and air quality....

  • Constant Temperature and Humidity Unit

    The Constant Temperature and Humidity Unit is a high-precision air conditioning device designed to maintain stable temperature and humidity in environments that require strict climate control. It...

  • Ceiling Air Conditioning Units

    The KD(X) series ceiling-mounted air handling units are terminal suspended air handling units for central air conditioning systems. They can filter, cool, dehumidify, heat, perform enthalpy...

  • Residential Air Handling Unit

    The Residential Air Handling Unit is a whole-house central air system specially designed for residential spaces including homes, apartments and villas. It integrates temperature regulation,...

  • Industrial Air Handling Unit

    The Industrial Air Handling Unit (referred to as Industrial AHU) is a modular air handling equipment specially designed for industrial scenarios and large public spaces. Its core function is to...

 
Why Choose Us

Advanced Equipment

The company operates a standardized modern production base with specialized lines for refrigeration equipment, fan coil units, and machine tools, ensuring efficient manufacturing and stable product quality.

Professional Team

We have a technical team with nearly 15 years of experience in the R&D and design of air handling units, fan coil units, and main units, and we have our own coil selection software and fan selection software.

Quality Control

By following standardized operations, our company has earned a 3A credit rating and passed major management system certifications, ensuring reliable quality and trusted service.

Customized Services

We provide professional air handling solutions tailored to different applications, making our products ideal supporting equipment for large-scale commercial and industrial projects.

 

Advantages of AHU

 

Enhanced Air Quality

Filters remove airborne contaminants.

01

Energy Efficiency

Variable-speed fans and energy recovery systems reduce power use.

02

Comfortable Environment

Maintains consistent temperature and humidity.

03

Lower Maintenance Costs

Centralized air handling reduces strain on smaller HVAC units.

04

Flexible Applications

AHUs provide airflow for any building.

05

 

Air Handling Unit

 

Components of AHU

Air intake: Air handling units collect air from outside, which is treated and distributed throughout the rooms; and/or indoor air that is "recycled".


Filter: Depending on the air purity requirements, the filter applied will have a higher or lower particle, viruses, bacteria, odours, and other air pollutants retention.


Fan: This is an electromechanical system that powers the air to expel it from the AHU to the ducts that distribute the air throughout the rooms.


Heat exchangers: Devices that transfer temperature between two fluids, in this case, coolant and air, separated by a solid barrier.


Cooling coil: The air passing through this module is cooled. In this process, water droplets can be generated, which are collected in a condensate tray thanks to the built-in droplet separator.


Silencer: Coatings that considerably reduce the sound level of the installation.


Plenums: Empty spaces in which the air flow is homogenised.

 

 

Types Of AHU

Horizontal and vertical units: Vertical units typically require less floor area.

 

Draw-through and blow-through units: The AHU is either a blow-through or draw-through mechanism depending on where the fan is located. The later AHU is the more commonly found.

 

Outdoor air (makeup air) or mixing units: While mixing units (as the name suggests) can utilise both recirculating air and outside air, makeup air units use only outdoor air.

 

Single-zone and multi-zone units: For dual-duct systems, a multi-zone AHU is more frequently employed

 

Rooftop and indoor units: There are specific AHU made for usage outside. They resist corrosion and are typically positioned on the roof. However, the majority of AHU are indoor units.

 

Custom-built and field-built units: Standard units are lower in cost and quicker to deliver. More versatility is available with custom-built AHU, which may also be made to be the most energy-efficient option.

Air Handling Unit (AHU)

 

Applications of AHU
 
Ceiling Air Conditioning Units
 

Commercial Buildings

AHUs maintain consistent indoor temperatures and air quality in office spaces, contributing to employee comfort and productivity.

 

Healthcare Facilities

AHUs ensure sterile and controlled environments in hospitals by regulating temperature, humidity, and air cleanliness.

Ceiling Air Conditioning Units factory
Residential Air Handling Unit
 

Industrial Plants

AHUs are used in manufacturing to regulate air temperature and humidity, ensuring optimal conditions for production processes.

 

Educational Institutions

Schools and universities utilize AHUs to create comfortable learning environments, particularly in regions with extreme weather.

Constant Temperature and Humidity Unit

 

Precautions

 

Power Supply Requirements

Please use standard power supply that conforms to the equipment specifications to prevent equipment damage and operational failures caused by unstable voltage.

 

Waterproof and Moisture-proof

Avoid installing the equipment in excessively humid environments to prevent electrical components from getting damp and ensure safe operation.

 

Regular Inspection

It is recommended to invite professional technicians to inspect pipelines and electrical systems regularly to eliminate potential hidden dangers and guarantee long-term safe operation.

 

Prohibit Unauthorized Modification

Do not disassemble or modify the internal structure of the equipment without permission. Please contact our professional technical staff for any adjustment requirements.

 
 

Packing Details

 

We will packing by professional export packing,safety against breakage, finally into the wooden cases/ carton/pallet or customized package.

 

productcate-891-367

 

Delivery Details

 

 

We can deliver by SEA,air,rail transportation,the China-Europe Railway Express etc. TNT, DHL,UPS, FEDEX, EMS,S.F EXPRESS etc.

 

 

Our Factory

 

The company operates a modern, standardized production base with specialized lines for refrigeration, fan coil units, and machine tools. Equipped with advanced CNC equipment, complete testing systems, and an ERP management system, it ensures efficient, precise, and coordinated production. A professional technical team and scientific management model guarantee stable quality and large-scale supply to meet global market demand.

 

productcate-1-1

 

 

Our Certificate

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
 

FAQ

 

Q: What is an Air Handling Unit (AHU)?

A: An Air Handling Unit (AHU) is a large rectangular metal box that conditions and circulates air in commercial buildings. It filters, cools or heats the air, and often replaces indoor air with fresh outdoor air to maintain air quality.

Q: What types of AHUs are available?

A: There are two primary types of AHUs: floor-mounted and ceiling-suspended. Floor-mounted AHUs are easier to access for maintenance, while ceiling-suspended AHUs save floor space but can be harder to service.

Q: How does the blower work in an AHU?

A: The blower is a fan that forces air through the ductwork into rooms. It is typically a centrifugal fan in AHUs, and its function is to ensure air is distributed effectively throughout the building.

Q: What are cooling coils in an AHU?

A: Cooling coils are components within an AHU designed to cool and dehumidify the air. They can use cold water or refrigerants to lower the temperature and remove moisture from the air.

Q: What role does the air filter play in an AHU?

A: Air filters in AHUs trap dust, debris, and allergens from the air, improving indoor air quality. Advanced filters can also remove pollen, bacteria, and other harmful particles.

Q: How does a damper function in an AHU?

A: Dampers are plates installed in the ducts of an AHU that regulate or stop the airflow. They help manage the volume of air entering or leaving the system, ensuring efficient air circulation.

Q: What is the difference between a blow-through AHU and a draw-through AHU?

A: In a blow-through AHU, the blower is positioned before the coils, pushing air through them, while in a draw-through AHU, the blower is placed after the coils, pulling air through them. Draw-through AHUs are more space-efficient and distribute airflow more evenly.

Q: How does a Building Management System (BMS) interact with AHUs?

A: A BMS centralizes control of HVAC equipment, including AHUs, allowing for remote monitoring and management. It uses sensors (like temperature, humidity, and pressure sensors) to optimize the operation of AHUs and ensure air quality and comfort.

Shandong Kasuo Air Conditioning Equipment Co., Ltd. is one of the most professional ahu manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to wholesale high-grade ahu for sale here from our factory. We also accept customized orders.

ac and air handler, ahu, air cooled ahu
Send Inquiry
Send Inquiry